Choose the correct Greenwald Pay installation kit
Source: Greenwald Pay Help Greenwald Pay Device Installation Instructions 4003-001-2 – Maytag /Whirlpool 4003-002-2 – Maytag /Whirlpool for Dual Coin 4004-001-2 – MDC/QTM for Dual Coin 4004-002-2 – MDC/QTM 4004-101-3 – ACA (No Power Supply) 4004-102-3 – ACA (2...
Install and provision Greenwald Pay hardware
Source: Greenwald Pay Help Prepare for the Install Important: Prior to installtion, set-up room and machine profiles in Greenwald Management System (GMS). Have ready: Greenwald Pay Device, Smart Phone, admin app credentials and screwdriver/operator key (to rem...
Troubleshoot Greenwald Pay setup and LED states
Source: Greenwald Pay Help Device LED Codes Color Activity Significance Off Off Device not connected to power White Slow Blink Device not configured Blue Steady Selected during configuration Yellow Slow Blink Loading machine configuration Green Steady Configur...
Install and provision EPIC MultiPay
Source: MultiPay Reader ACA install INS.2487-1 Searchable installation guide with supporting visuals
Troubleshoot EPIC MultiPay
Source: MultiPay Reader ACA install INS.2487-1 Admin - MultiPay Device LED Codes Color Activity Significance Off Off Device not connected to power White Slow Blink Device not configured Blue Steady Selected during configuration Yellow Slow Blink Loading machin...
Install GPay kit 4003-001-2 on Maytag or Whirlpool machines
Install the Greenwald Pay device through the serial port on the Maytag or Whirlpool machine control board. Kit: 4003-001-2 Installation sheet: INS. 2475-4 Rev A Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to ...
Install GPay kit 4003-002-2 on Maytag or Whirlpool dual-coin machines
Install the Greenwald Pay device between the Maytag or Whirlpool control board and both coin drops. Kit: 4003-002-2 Installation sheet: INS. 2475-5 Rev B Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to open th...
Install GPay kit 4004-001-2 on MDC or Quantum dual-coin machines
Install the Greenwald Pay Plus device between the MDC/Quantum control board and coin drop. Kit: 4004-001-2 Installation sheet: INS. 2472-3 Rev A Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to open the machine...
Install GPay kit 4004-002-2 on MDC or Quantum machines
Connect the Greenwald Pay Plus device to the MDC/Quantum control board and existing card reader. Kit: 4004-002-2 Installation sheet: INS. 2472-4 Rev A Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to open the m...
Install GPay kit 4004-101-3 on ACA machines without a power supply
Connect the Greenwald Pay device directly to the ACA machine control board. Kit: 4004-101-3 (No Power Supply) Installation sheet: INS. 2473-4 Rev B Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to open the mach...
Install GPay kit 4004-102-3 on ACA machines with 24 VAC power conditioner
Connect the Greenwald Pay device and its 24 VAC power conditioner to the ACA control board. Kit: 4004-102-3 (24 VAC Power Conditioner) Installation sheet: INS. 2473-5 Rev B Installation layout What you need Greenwald Pay machine labels Appropriate tool or oper...
Install GPay kit 4016-001-2 on LG dual-coin machines
Install the Greenwald Pay device between the LG control panel and both coin drops. Kit: 4016-001-2 Installation sheet: INS. 2476-2 Rev A Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to open the machine panel S...
Install GPay kit 4210-001-2 on Encore dual-coin dryers
Connect the Greenwald Pay device to the Encore pulse-dryer control board and dual-coin device. Kit: 4210-001-2 (Dual Coin) Installation sheet: INS. 2477-1 Rev B Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to ...
Install GPay kit 4210-002-2 on Encore dual-coin washers
Connect the Greenwald Pay device to the Encore pulse-washer control board and dual-coin device. Kit: 4210-002-2 (Dual Coin) Installation sheet: INS. 2477-2 Rev B Installation layout What you need Greenwald Pay machine labels Appropriate tool or operator key to...
Enable serial payment on Alliance Quantum Gold Pro machines
Enable Serial Payment on Alliance Quantum Gold Pro (Titanium) controls so Greenwald Pay devices and Greenwald contact-card readers can communicate with the machine. Procedure: INS. 2486 Rev A Frequency: Complete once unless machine settings are changed later I...
Greenwald Pay GMS Quick Start Guide (2021)
Use Greenwald Management System (GMS) to configure users, accounts, locations, machine profiles, devices, collections, and reports. Guide date: July 9, 2021 Supported browsers in the guide: Google Chrome, Firefox, and Microsoft Edge Sign in Open GMS. Enter you...
Install MultiPay Reader on Alliance ACA machines - INS.2487-1 Rev B